WASTEWATER ENGINEERING MCQ Civil Engineering

 WASTEWATER ENGINEERING MCQ Civil Engineering'


Highway engineering MCQ Pdf Download now

1. For a continuous flow type of sedimentation tanks
(A) Width of the tank is normally kept about 6 m
(B) Length of the tank is normally kept 4 to 5 times the width
(C) Maximum horizontal flow velocity is limited to 0.3 m/minute
(D) All the above
Answer:(D)
2. The asbestos cement sewers are
(A) Light in weight
(B) Not structurally strong to bear large compressive stress
(C) Susceptible to corrosion by sulphuric acid
(D) All the above
Answer:(D)
3. For efficient working of a sewer, it must be ensured that
(A) Minimum velocity of 0.45 m/sec, is maintained at its minimum flow
(B) A maximum velocity of 0.90 m/sec, is maintained at its maximum flow
(C) Both (a) and (b)
(D) Neither (a) nor (b)
Answer:(C)
4. Pick up the correct statement from the following:
(A) The sewer pipes of sizes less than 0.4 m diameter are designed as running full at maximum discharge
(B) The sewer pipes of sizes greater than 0.4 m diameter are designed as running 2/3rd or 3/4th full at
maximum discharge
(C) The minimum design velocity of sewer pipes is taken as 0.8 m/sec
(D) All the above
Answer:(D)
5. Pick up the correct statement from the following:
(A) Maximum daily flow = 2 times the average daily flow
(B) Maximum daily flow = ⅔ × average daily flow
(C) Sewers are designed for minimum permissible velocity at minimum flow
(D) All the above
Answer:(D)
6. Bottom openings 15 cm × 15 cm in the standing baffle wall are provided
(A) 15 cm c/c
(B) 22.5 cm c/c
(C) 30 cm c/c
(D) 50 cm c/c
Answer:(B)
7. The pressure exerted by
(A) The sewage when running full from inside, is called internal pressure
(B) The internal pressure if any, causes tensile stress in the pipe material
(C) Pressure sewers are designed to be safe in tension
(D) All the above
Answer:(D)

8. For drainage pipes in buildings the test applied before putting them to use, is
(A) Water test
(B) Smoke test
(C) Straightness test
(D) All the above
Answer:(B)
9. No treatment of the sewage is given if dilution factor is
(A) Less than 150
(B) Between 150 to 200
(C) Between 200 to 300
(D) More than 500
Answer:(D)
10. Which of the following pumps in used to pump sewage solids with liquid sewage without clogging
the pump is?
(A) Centrifugal pump
(B) Pneumatic ejector
(C) Reciprocating pump
(D) None of these
Answer:(A)
Part 2 Click here to attempt]



homeacademy

Home academy is JK's First e-learning platform started by Er. Afzal Malik For Competitive examination and Academics K12. We have true desire to serve to society by way of making educational content easy . We are expertise in STEM We conduct workshops in schools Deals with Science Engineering Projects . We also Write Thesis for your Research Work in Physics Chemistry Biology Mechanical engineering Robotics Nanotechnology Material Science Industrial Engineering Spectroscopy Automotive technology ,We write Content For Coaching Centers also infohomeacademy786@gmail.com