Final Report of project HVAC Design for a 3BHK Residential House

 

 Detailed explanation of the Final Project for designing a complete HVAC system, covering both a 3BHK house (residential) and a small office (commercial). This includes load calculation, equipment selection, duct layout, IAQ (Indoor Air Quality) considerations, and design steps.




🏠 A. HVAC Design for a 3BHK Residential House

🔹 1. Basic Assumptions:

RoomSize (in ft)OccupantsOrientationWindows
Bedroom 112 × 12 × 102West1
Bedroom 212 × 14 × 102South1
Bedroom 310 × 12 × 101North1
Living Room14 × 16 × 104East2
Kitchen10 × 10 × 101East1

🔹 2. Load Calculation

Use Manual J method for residential load:

✅ Formula:


Cooling Load (BTU/hr) ≈ Area × 30–40 BTU/hr (typical)

Rough Estimate:

 (People, Lights, Appliances): ~3,000 BTU/hr

👉 Total Cooling Load ≈ 30,000 BTU/hr
(= 2.5 Tons)


🔹 3. Equipment Selection

Room TypeEquipment
Bedrooms1 Ton Split AC each
Living + Dining1.5 Ton Split AC
KitchenExhaust fan, cross-ventilation

Total Units:

  • 3 × 1 Ton + 1.5 Ton = 4.5 Tons of Cooling


🔹 4. Duct Design Layout (Optional - for Central AC)

For ducted AC system (instead of splits):

Use flexible ducts or rectangular sheet metal ducts.

Maintain air velocity = 700–900 FPM.
Use supply diffusers in the center of rooms, returns at wall level.

Basic layout:


[Bedroom 1] [Bedroom 2]
| | [ Duct ]-------[Living Room]----[Bedroom 3] | [ AHU/Furnace ] | [Outdoor Condenser]

🔹 5. IAQ Considerations

Fresh Air Inlet: Small fresh air duct with filter.

Exhaust Fan: In kitchen and bathroom.
Air Filters: MERV 8–11 filters.
Humidity Control: Use of dehumidifier in monsoon season.

🏢 B. HVAC Design for a Small Office (Commercial)

🔹 1. Assumptions

AreaSize (ft²)OccupantsEquipment (W)
Reception1502300
Work Area60061500
Cabin1501300
Conference20061000

🔹 2. Load Calculation (Use Manual N for commercial)

Components:

Area Load: Total 1100 ft² × 35 BTU/hr = 38,500 BTU/hr

People Load: 15 people × 400 BTU/hr = 6,000 BTU/hr
Equipment Load: ~3000 BTU/hr
Lighting Load: 1100 ft² × 3 W/ft² × 3.41 = ~11,000 BTU/hr

👉 Total ≈ 58,500 BTU/hr4.9 Tons5 Ton AC needed


🔹 3. Equipment Selection

Central Ducted Package Unit or VRF/VRV System

ZoneSuggested Unit
Work Area2 Ton cassette type
Conference Room1.5 Ton wall mount
Reception/Cabin1.5 Ton combined

🔹 4. Duct Design Layout

Use ducted central unit with VAVs for zoning.

Air velocity = 1000–1200 FPM for commercial ducts.
Duct material: GI sheet metal.

Example Layout:



[AHU/Package Unit] | [Main Duct] / | \ Rec Work Conf

Supply Vents: Each room

Return Air Duct: Common return to AHU
Fresh Air Intake: Through treated fresh air (TFA) unit

🔹 5. IAQ Considerations

CO₂ Sensors for occupancy-based ventilation

HEPA or MERV 13 filters
UV Lights in ducts to kill microbes
Fresh Air Ventilation: 15–20 CFM/person
Humidity Control: Maintain RH 40–60%

📐 Summary of Design Parameters

ParameterResidential (3BHK)Small Office
Cooling Load2.5 Tons5 Tons
Equipment TypeSplit / CentralVRF / Ducted
Air Flow Rate400 CFM/ton400 CFM/ton
Air Changes4–6 per hour6–10 per hour
Fresh Air RequiredBasic VentilationTFA system
FiltrationMERV 8–11MERV 13+

🛠 Final Deliverables

1. Load Calculation Sheet
2. Equipment List with Specs
3. Duct Layout Diagram
4. IAQ Measures Plan
5. Energy Efficiency Notes (e.g., inverter AC, insulation, zoning)



homeacademy

Home academy is JK's First e-learning platform started by Er. Afzal Malik For Competitive examination and Academics K12. We have true desire to serve to society by way of making educational content easy . We are expertise in STEM We conduct workshops in schools Deals with Science Engineering Projects . We also Write Thesis for your Research Work in Physics Chemistry Biology Mechanical engineering Robotics Nanotechnology Material Science Industrial Engineering Spectroscopy Automotive technology ,We write Content For Coaching Centers also infohomeacademy786@gmail.com